Comparison of a Human Portable Blood Glucose Meter and Automated Chemistry Analyzer for Measurement of Blood Glucose Concentrations in Human Diabetic Patients / (Record no. 607444)
[ view plain ]
| 000 -LEADER | |
|---|---|
| fixed length control field | 02287nam a22001577a 4500 |
| 082 ## - DEWEY DECIMAL CLASSIFICATION NUMBER | |
| Classification number | 610 |
| 100 ## - MAIN ENTRY--PERSONAL NAME | |
| Personal name | Asad-Ur-Rehman |
| 245 ## - TITLE STATEMENT | |
| Title | Comparison of a Human Portable Blood Glucose Meter and Automated Chemistry Analyzer for Measurement of Blood Glucose Concentrations in Human Diabetic Patients / |
| Statement of responsibility, etc. | Asad-Ur-Rehman |
| 264 ## - PRODUCTION, PUBLICATION, DISTRIBUTION, MANUFACTURE, AND COPYRIGHT NOTICE | |
| Place of production, publication, distribution, manufacture | Islamabad : |
| Name of producer, publisher, distributor, manufacturer | SMME- NUST; |
| Date of production, publication, distribution, manufacture, or copyright notice | 2023. |
| 300 ## - PHYSICAL DESCRIPTION | |
| Extent | 46p. |
| Other physical details | Islamabad : SMME- NUST; Soft Copy |
| Dimensions | 30cm |
| 500 ## - GENERAL NOTE | |
| General note | Diabetes is the most prevalent chronic metabolic disorder in Pakistan which is<br/>characterized by an increased Blood Glucose level. An accurate diagnosis of diabetes is<br/>very essential for its early detection and treatment. Almost 90\% of the cases are of Type<br/>II Diabetes and the patients are required to continuously monitor their Blood Glucose<br/>level to maintain a near-normal range of Blood sugar. A practical way to monitor sugar<br/>levels is using a portable Glucometer at home which is faster and more convenient for<br/>diabetes patients. The purpose of this study is to compare Blood Glucose levels measured<br/>using Oxidase Method and a Portable Glucometer with reference Hexokinase Method in<br/>Type II Diabetes patients to determine if Glucometers can be used as a home-based selfmonitoring device. A cross-sectional study was conducted with a total of 150 Type II<br/>Diabetes patients. Blood samples were collected from the capillary of fingers for a<br/>portable Glucometer and from veins for Hexokinase and Oxidase Plasma methods after<br/>overnight fasting of 8 hours. Independent t-test and Pearson Correlation were used to<br/>check the significance of our results. There was no statistically significant difference in<br/>Blood Glucose readings obtained from Oxidase Method (128.31 + 61.4, p = 0.947) and<br/>Glucometer (122.53 + 59.6, p = 0.370) with Reference Hexokinase Method (128.78 +<br/>61.2). A statistically significant positive correlation was observed in both methods with<br/>reference Hexokinase Method. Glucometer readings positively correlate with<br/>Hexokinase, showing that Glucometer can be used as a home-based self-monitoring<br/>Blood Glucose Device. |
| 650 ## - SUBJECT ADDED ENTRY--TOPICAL TERM | |
| Topical term or geographic name entry element | MS Biomedical Sciences (BMS) |
| 700 ## - ADDED ENTRY--PERSONAL NAME | |
| Personal name | Supervisor : Dr. Muhammad Asim Waris |
| 856 ## - ELECTRONIC LOCATION AND ACCESS | |
| Uniform Resource Identifier | <a href="http://10.250.8.41:8080/xmlui/handle/123456789/32674">http://10.250.8.41:8080/xmlui/handle/123456789/32674</a> |
| 942 ## - ADDED ENTRY ELEMENTS (KOHA) | |
| Source of classification or shelving scheme | |
| Koha item type | Thesis |
| Withdrawn status | Permanent Location | Current Location | Shelving location | Date acquired | Full call number | Barcode | Koha item type |
|---|---|---|---|---|---|---|---|
| School of Mechanical & Manufacturing Engineering (SMME) | School of Mechanical & Manufacturing Engineering (SMME) | E-Books | 01/19/2024 | 610 | SMME-TH-840 | Thesis |